Call Now
OEM Parts appliance repair

OEM Parts

Whirlpool Dryer Repair Near You — Full Brand List

Local Whirlpool technicians ready to fix your Dryer near you. Same-day appointments available.

Licensed & insured in TexasSame-day slots90-day parts warrantyAll Houston home types served
(832) 446-4724

Mon–Fri 7am–7pm · Sat 8am–5pm

Request a RepairStep 1 of 2
01 The job
02 Your details
Property
01Property
Where
02Where
What needs fixing
03What needs fixing

Prefer to talk? (832) 446-4724

90-Day
Parts Warranty
Same Day
Availability

Manufacturers We Are Trained On

Samsung appliance repairLG appliance repairWhirlpool appliance repairGE appliance repairBosch appliance repairMaytag appliance repairFrigidaire appliance repairElectrolux appliance repairKenmore appliance repairAmana appliance repairSpeed Queen appliance repairMiele appliance repairFisher & Paykel appliance repair
Houston Repair Technicians

Built for Houston — Homes, Condos & More

True Fix Houston is your local provider for Whirlpool Dryer repair. Our neighborhood technicians work on Whirlpool equipment and access to genuine OEM parts. We repair all Whirlpool Dryer models, handle all common problems, and back our work with a 90-day parts and 30-day labor warranty. Book online or call for same-day service near you.

Colonial & Ranch
Houston's most common homes — we service full-size appliances across Greater Houston.
Condo / Townhouse
HOA-approved. Insurance certificates & board documentation on request.
Same-Day Service
Call before noon for today's slot across all Houston zip codes.
All Major Brands
Samsung, LG, Sub-Zero, Miele, Viking & 40+ more.
Upfront Pricing
Flat-rate quotes before work starts — no surprise charges.
90-Day Warranty
90 days on parts, 30 days on labor. We return at no charge if the fix fails.
Licensed & insured in Texas
State-licensed, fully bonded & insured
HOA & Board Ready
Insurance certificates on request
Flexible Scheduling
Mon–Fri 7am–7pm · Sat 8am–5pm
Upfront Fixed Pricing
No hidden fees — price locked before we start

How a Call Actually Goes

01
Start With a Call or the Form
Schedule in 2 min or call (832) 446-4724
02
Tech Arrives
Usually same day in a 3-hr window
03
Diagnose & Quote
Upfront price — no work without approval
04
Fix & Test
Repair done, tested before we leave

Whirlpool dryer repair: what to know

Whirlpool makes vented electric and gas dryers, plus ventless and HybridCare heat pump models, and shares much of its dryer engineering with sister brands in Whirlpool Corporation. On models with a display, Whirlpool uses short codes that are easy to misread. AF, also shown as F4E3 or Check Vent, means airflow is restricted. L2 means low or no line voltage reaching the heater. PF means the power was interrupted mid-cycle. Any other F and E pair means the control has found a fault that needs service. PF is a common sight in Houston after a storm. At its peak after landfall on July 8, 2024, Hurricane Beryl knocked out power to more than 2.26 million CenterPoint Energy customers, and even short flickers can stop a cycle. Common repair calls include slow drying with an AF warning, cold air from an electric model, and a drum that hums but will not turn.

Faults we see on Whirlpool dryers

Restricted airflow (AF / F4E3)

Drying takes much longer and the display shows AF or Check Vent. Whirlpool traces it to a clogged lint screen, a vent clogged with lint, or a duct that is crushed, kinked or has too many turns. The technician measures airflow at the outside hood, clears or reroutes the duct, and checks the blower wheel inside the dryer for packed lint.

Low line voltage (L2)

The dryer runs but the heat never comes on, and L2 appears. Whirlpool's guidance starts with a blown fuse or tripped breaker, then the power cord installation. One dead leg of the 240-volt supply is a common cause. If the supply measures correctly at the terminal block, the technician checks the cord connections for heat damage and the control's voltage sensing.

No heat on a gas model

The drum turns but stays cool. A gas dryer makes its heat with a burner rather than a 240-volt element, so the checks are different. Watch through the vent holes: if the igniter glows and fades without a flame, the gas valve coils are usually at fault. If it never glows, the technician tests the igniter, the flame sensor and the thermal fuse before changing anything.

Motor hums, drum does not turn

You hear a hum or a loose spinning sound, but the drum stays still. A broken drive belt, or an idler pulley that has seized, is the usual cause. The belt can also come off a worn pulley. The technician opens the cabinet, replaces the belt and inspects the pulley, rollers and motor shaft so the new belt does not fail early.

Squeaking or thumping drum

A rhythmic squeak or thump gets worse as the dryer warms up. Worn drum support rollers, a dry idler pulley and worn glides at the front of the drum are the usual sources. The technician spins the drum by hand with the belt off to find the worn part, and replaces rollers in pairs.

Check these before you call

  • Empty the Whirlpool lint screen each load and scrub it in soapy water every few months.
  • Slide the machine out a foot and inspect the transition duct for flattening.
  • With a cycle running, stand at the exterior hood: the flap should lift and you should feel a firm stream.
  • On L2 or cold air, flip both halves of the 240-volt breaker off, wait, then back on.
  • After a PF code, touch and hold START to resume before assuming a fault.

Whirlpool dryer error codes

CodeMeaningTry first
AF or F4E3Restricted airflow: the lint screen or vent is clogged, or the vent is crushed, kinked or has too many turns.Clean the lint screen and check the vent run and outside hood for lint and kinks.
L2Low or no line voltage; the home power supply may be keeping the heater from turning on.Check for a blown fuse or tripped breaker and confirm the power cord is properly installed.
PFA power failure interrupted the drying cycle.Touch and hold START to restart the cycle, or press POWER to clear the display.
F# E#The dryer control has detected a problem that requires service.Note the full code and book service; it identifies the part the control flagged.

From Whirlpool's own documentation; codes vary by model, so check your manual.

Finding the model number

Whirlpool puts the model and serial label inside the dryer door, on the rim of the door opening; on ventless models it is behind the water tank. Having it ready lets the technician bring the right part on the first visit.

Repair it or replace it?

Whirlpool dryers share parts with other Whirlpool Corporation brands, so belts, rollers, thermal fuses, elements, igniters and gas valve coils are easy to source and quick to fit. Nearly every one of those repairs is worth doing. Replacement is worth considering when a main control fails on an older dryer, or when the drum has worn through. A heat pump or HybridCare model is also more expensive to repair if its sealed system fails, so we compare costs before going ahead with that work.

Whirlpool dryer questions

My Whirlpool dryer shows PF after the power flickered. Is it damaged?

Usually not. PF just records that a power interruption stopped the cycle. Whirlpool's guidance is to touch and hold START to resume, or press POWER to clear the display. After a longer outage, check the breaker before restarting. If the dryer will not heat or start after the power has been back for a while, book a check.

Can I keep using the dryer while it shows AF?

It will keep drying, but slowly. Restricted airflow also means more heat and lint build up inside the machine. Start with the screen, then follow the duct from the back panel to the wall and finally the hood outside. If the warning comes back with a clean screen, the duct needs clearing or rerouting. Do not leave the dryer running unattended in the meantime.

Why does my dryer show L2 when the drum still turns?

On an electric dryer the motor typically runs on one 120-volt leg, while the heating element needs both legs of the 240-volt supply. Lose one leg and you get tumbling with cold air, which the control flags as L2. Reset the double breaker fully off and on, or replace a blown fuse. If L2 continues, the outlet, the cord or the terminal block needs checking.

Whirlpool Dryer Problems We Fix

Not Heating
Drum Not Tumbling
Takes Too Long to Dry
Making Loud Noise
Won't Start
Dryer Overheating
Not Drying Clothes
Shutting Off Early
Not Getting Hot Enough
Taking Too Long to Dry
Thermal Fuse Blown
Heating Element Burned Out
Gas Igniter Not Working
Gas Valve Solenoid Failure
Flame Sensor / Radiant Sensor Failure
Blower Wheel Clogged with Lint
Exhaust Duct Clogged
Restricted Exhaust Airflow
Dryer Venting Improperly
Drive Belt Broken
Drum Rollers Worn Out
Drum Glide / Bearing Worn
Idler Pulley Seized
Drive Motor Failure
Making Loud Noise During Operation
Squealing Noise During Tumble
Thumping or Banging Noise
Rattling Noise
Control Board Failure
Cycling Thermostat Failure
High-Limit Thermostat Failure
Moisture Sensor Failure
Dryer Door Not Closing Properly
Door Switch Failure
Lint Trap / Screen Damaged
Start Button Not Working
Dryer Won't Turn On
Tripping Circuit Breaker
Burning Smell
Clothes Shrinking
Clothes Still Wet After Full Cycle
Clothes Damp but Warm After Cycle
Auto-Dry Sensor Not Working
Timer Not Advancing
Electric Dryer No Heat — Partial Power
Gas Smell from Gas Dryer
Display Panel Not Working
Buttons Not Responding
Won't Spin at All
Stops Mid-Cycle
Heat Setting Not Changing
Excessive Energy Use
Excessive Static on Clothes
Clothes Heavily Wrinkled
Steam Function Not Working
Moisture Sensor Needs Cleaning
Exhaust Hose Kinked
Exterior Too Hot to Touch
Wrinkle-Prevent Tumble Not Working
Requires Two or More Cycles to Dry
Error Code on Display
Low Gas Pressure to Dryer
Drum Interior Light Not Working
Door Handle Broken
Auto-Dry Cycle Runs All Night
Gas Burner Orifice Clogged
Lint Fire Hazard in Ductwork
Timer Advancing Too Slowly
Three-Prong Outlet / Four-Prong Cord Mismatch
Knocking at Startup
Intermittent Squeaking
Bird or Pest Nest in Dryer Duct
Cycling Thermostat Stuck Closed
Gas Valve Solenoid Kit Needed
Thermal Cutout Needs Resetting
CallBook