OEM Parts
LG Dryer Repair Near You — Full Brand List
Local LG technicians ready to fix your Dryer near you. Same-day appointments available.
Mon–Fri 7am–7pm · Sat 8am–5pm
Built for Houston — Homes, Condos & More
True Fix Houston is your local provider for LG Dryer repair. Our neighborhood technicians work on LG equipment and access to genuine OEM parts. We repair all LG Dryer models, handle all common problems, and back our work with a 90-day parts and 30-day labor warranty. Book online or call for same-day service near you.
How a Call Actually Goes
Related Services
Houston technicians across every appliance and brand we cover.
LG dryer repair: what to know
LG dryers are built around a sensor-heavy design: a humidity sensor below the lint filter decides when clothes are dry, thermistors watch temperature, and on many models a Flow Sense system measures exhaust restriction and reports it as d75, d80, d90 or d95, the number standing for how clogged the vent is. Steam models add a water inlet or a refillable steam feeder, and newer units carry Wi-Fi modules. That design gives owners plenty of information before a technician arrives, and LG's own code list is detailed. The catch is that many LG dryer complaints are not dryer faults at all. An overlong exhaust route, a flattened foil hose behind the cabinet, or lint lining the wall pipe will produce long cycles and a Flow Sense warning just as reliably as a broken part. Houston's humidity already slows drying, so in a laundry closet or garage installation, a restricted vent shows up quickly as clothes that need a second cycle.
Faults we see on LG dryers
d80 or d90 and slow drying
LG describes these codes as the exhaust duct being clogged to the stated percentage. Lint in the filter housing, a kinked transition duct, or a wall vent flap stuck shut are the common reasons. The technician measures airflow, follows the exhaust to its termination, and cleans the dryer's internal duct.
No heat on an electric model
If the drum turns but stays cold, the heater element, a high-limit thermostat or a thermal fuse may have opened, often because of the same vent restriction. LG's nP code points to no current at the heater. The tech checks power at the terminal block, the element's resistance, and the safety devices before replacing anything.
Clothes damp but cycle ends early
LG's sensor-dry cycles rely on metal strips below the lint filter. Fabric softener residue coats them and the dryer stops too soon. LG's HS code points to a humidity sensor error. The technician cleans the sensors, checks their wiring, and confirms readings at the control.
Thumping or squealing drum
A worn drum support roller, a dried idler pulley or a stretched belt makes rhythmic noise that grows over time. The tech opens the cabinet, spins the drum by hand, and replaces worn rollers or the belt as a set where appropriate.
Gas dryer heats briefly then cools
On gas models, failing gas valve coils can let the igniter light the burner once and then stop. LG's GAS code indicates no gas supply. The technician confirms the supply valve is open, watches the ignition sequence, and tests the valve coils and flame sensor.
Check these before you call
- Pull the lint filter and look into the housing with a flashlight; lint collects below the filter, not just on it.
- Slide the dryer out and straighten any crushed or kinked duct behind it.
- Stand at the exterior hood during a cycle and feel for a strong, warm blast.
- Wipe the metal sensor bars below the lint filter with a little rubbing alcohol.
- On gas models, check the gas shut-off valve handle is in line with the pipe.
LG dryer error codes
| Code | Meaning | Try first |
|---|---|---|
| d80 / d90 / d95 | The exhaust duct is clogged to roughly that percentage, as detected by Flow Sense. | Clean the lint filter and check the rear exhaust duct and outside vent for blockages. |
| nP | No current at the heater, usually an electrical wiring problem. | Make sure the power cord is securely plugged into a grounded outlet and check the breaker. |
| HS | Humidity sensor error. | Clean the sensor strips inside the dryer below the lint filter. |
| tE1 | Thermistor problem. | Unplug the dryer, hold Start/Pause for five seconds, then restore power. |
| GAS | No gas supply to the unit. | Make sure the gas supply valve to the dryer is turned on. |
| PS | Improper voltage, often reversed white and red wires at the terminal block. | Have the power cord installation at the terminal block checked. |
From LG's own documentation; codes vary by model, so check your manual.
Finding the model number
LG says to open the dryer door and check the silver label at the top of the door opening for the model and serial number. Having it ready lets the technician bring the right part on the first visit.
Repair it or replace it?
Most LG dryer repairs involve modest parts: thermal fuses, high-limit thermostats, heater elements, igniters, rollers and belts. Those are worth doing on almost any dryer whose drum and cabinet are sound. An ageing LG with a dead main board, or a rear drum bearing gone alongside other wear, is where replacement deserves a look. If the vent caused the failure, fix the vent too, or the new part will fail the same way.
LG dryer questions
My LG shows d80 but the lint filter is clean. Why?
The code measures the whole exhaust path, not just the filter. Lint below the filter, a long or crushed duct behind the dryer, or a blocked outside vent all trigger it. Have the full run inspected and cleaned; once airflow improves, the code should clear and drying times should drop.
Why does my LG dryer stop before the clothes are dry?
Sensor-dry cycles use metal strips to judge moisture. Softener sheets and liquid softener leave a film that fools them. Clean the strips, and if loads are still damp, try a timed cycle to check that the heater is working. An HS code points directly to the sensor.
Is a Flow Sense warning dangerous?
It is a warning that exhaust is restricted, so the machine runs hot and long while lint accumulates. Lint is flammable, so a restricted vent should be cleaned promptly rather than ignored. Running the dryer with a seriously blocked vent can also trip the thermal fuse.