Call Now
OEM Parts appliance repair

OEM Parts

Maytag Dryer Repair Near You — Full Brand List

Local Maytag technicians ready to fix your Dryer near you. Same-day appointments available.

Licensed & insured in TexasSame-day slots90-day parts warrantyAll Houston home types served
(832) 446-4724

Mon–Fri 7am–7pm · Sat 8am–5pm

Request a RepairStep 1 of 2
01 The job
02 Your details
Property
01Property
Where
02Where
What needs fixing
03What needs fixing

Prefer to talk? (832) 446-4724

90-Day
Parts Warranty
Same Day
Availability

Manufacturers We Are Trained On

Samsung appliance repairLG appliance repairWhirlpool appliance repairGE appliance repairBosch appliance repairMaytag appliance repairFrigidaire appliance repairElectrolux appliance repairKenmore appliance repairAmana appliance repairSpeed Queen appliance repairMiele appliance repairFisher & Paykel appliance repair
Houston Repair Technicians

Built for Houston — Homes, Condos & More

True Fix Houston is your local provider for Maytag Dryer repair. Our neighborhood technicians work on Maytag equipment and access to genuine OEM parts. We repair all Maytag Dryer models, handle all common problems, and back our work with a 90-day parts and 30-day labor warranty. Book online or call for same-day service near you.

Colonial & Ranch
Houston's most common homes — we service full-size appliances across Greater Houston.
Condo / Townhouse
HOA-approved. Insurance certificates & board documentation on request.
Same-Day Service
Call before noon for today's slot across all Houston zip codes.
All Major Brands
Samsung, LG, Sub-Zero, Miele, Viking & 40+ more.
Upfront Pricing
Flat-rate quotes before work starts — no surprise charges.
90-Day Warranty
90 days on parts, 30 days on labor. We return at no charge if the fix fails.
Licensed & insured in Texas
State-licensed, fully bonded & insured
HOA & Board Ready
Insurance certificates on request
Flexible Scheduling
Mon–Fri 7am–7pm · Sat 8am–5pm
Upfront Fixed Pricing
No hidden fees — price locked before we start

How a Call Actually Goes

01
Start With a Call or the Form
Schedule in 2 min or call (832) 446-4724
02
Tech Arrives
Usually same day in a 3-hr window
03
Diagnose & Quote
Upfront price — no work without approval
04
Fix & Test
Repair done, tested before we leave

Maytag dryer repair: what to know

Maytag dryers sit in Whirlpool Corporation's laundry family, built around familiar drum, belt and idler designs with gas or electric heat. Maytag's support pages list a short set of display codes: AF or F4E3 for restricted airflow, PF for a power failure during a cycle, L2 for low or no line voltage, and F-and-E combinations that need a technician. Those codes cover several of the most frequent calls. AF in particular points straight at the vent, which in Houston homes often runs a long way through attic or wall cavities and collects lint quickly in humid conditions. L2 is useful too, since an electric dryer losing one leg of power will tumble but not heat. Owners usually notice long drying times or a hot laundry room first, and the code on the display usually tells you whether to start with the vent or the breaker.

Faults we see on Maytag dryers

AF or F4E3 on the display

Maytag says this indicates restricted airflow from a clogged lint screen or vent, or a vent that is crushed, kinked or has too many turns. A technician checks airflow at the outside hood, cleans the duct, and looks for long runs or flex hose behind the dryer before suspecting sensors.

Tumbles but no heat

With electric heat, one dead leg of the double breaker or an open failed heating element stops heat while the drum still turns. On gas versions, the glowing igniter or the valve solenoid coils may be the cause. L2 on the display points to supply voltage. The tech measures voltage at the terminal block and tests the heat circuit.

Squealing or thumping drum

Worn drum rollers, a glazed belt or a tired idler pulley make rhythmic thumps or high squeals. The drum is removed and each roller and pulley is spun by hand to find the worn part.

Dryer stops mid-cycle

A dryer that runs then stops, especially with clothes still damp, often has a failing thermal fuse, an overheating motor, or a door switch issue. Vent restriction is checked because overheating is a common cause.

Cycle interrupted, PF shown

PF means the cycle was interrupted by a power failure. After a storm or a brief outage, the dryer simply needs a restart. Repeated PF without an outage suggests a loose cord or terminal connection, which is inspected.

Check these before you call

  • Pull lint off the screen each load, and scrub it under the tap now and then if dryer sheets leave a film.
  • Go outside and feel for strong airflow from the vent hood while the dryer runs.
  • Check the breaker for an electric dryer; both halves of a double breaker must be on.
  • Make sure the gas valve is open for a gas dryer.
  • Straighten any crushed or kinked flex duct behind the dryer.

Maytag dryer error codes

CodeMeaningTry first
AF or F4E3Restricted airflow: the lint screen or vent is clogged, or the vent is crushed, kinked or has too many turns.Empty the lint screen, then look along the duct for lint plugs and bends.
L2Low or no line voltage; there may be a problem with the home power supply.Check whether a household fuse has blown or the breaker has tripped.
PFPower failure: the drying cycle was interrupted by a power failure.Touch and hold START to restart the cycle, or press POWER to clear the display.
F# E#The dryer control has detected a problem that requires service.Record the full code and schedule service.

From Maytag's own documentation; codes vary by model, so check your manual.

Repair it or replace it?

Maytag dryers are straightforward to repair. Belts, rollers, idlers, heating elements, igniters, thermal fuses and door switches are good value at almost any age. Board or drive-motor failure on a high-mileage machine is the main decision point. Fixing a restricted vent before or alongside any repair protects the new parts and keeps drying times short.

Maytag dryer questions

My Maytag dryer shows AF. Do I need a technician?

Not right away. Start with the screen and the duct, looking for crushing, kinks or lint. If the vent is long or runs through the attic, a professional cleaning may be needed. If the code persists after the vent is clear, have the dryer inspected.

What does L2 mean on my dryer?

Maytag uses L2 to signal low or no line voltage. Check the breaker and fuses. With electric models, a single side of the breaker may trip, leaving the drum turning without heat.

Towels need a second run in my Maytag. What gives?

Restricted airflow is the most frequent reason, followed by a weak heating element or igniter. Check the vent and lint screen first. If airflow is good, the heat circuit should be tested.

Maytag Dryer Problems We Fix

Not Heating
Drum Not Tumbling
Takes Too Long to Dry
Making Loud Noise
Won't Start
Dryer Overheating
Not Drying Clothes
Shutting Off Early
Not Getting Hot Enough
Taking Too Long to Dry
Thermal Fuse Blown
Heating Element Burned Out
Gas Igniter Not Working
Gas Valve Solenoid Failure
Flame Sensor / Radiant Sensor Failure
Blower Wheel Clogged with Lint
Exhaust Duct Clogged
Restricted Exhaust Airflow
Dryer Venting Improperly
Drive Belt Broken
Drum Rollers Worn Out
Drum Glide / Bearing Worn
Idler Pulley Seized
Drive Motor Failure
Making Loud Noise During Operation
Squealing Noise During Tumble
Thumping or Banging Noise
Rattling Noise
Control Board Failure
Cycling Thermostat Failure
High-Limit Thermostat Failure
Moisture Sensor Failure
Dryer Door Not Closing Properly
Door Switch Failure
Lint Trap / Screen Damaged
Start Button Not Working
Dryer Won't Turn On
Tripping Circuit Breaker
Burning Smell
Clothes Shrinking
Clothes Still Wet After Full Cycle
Clothes Damp but Warm After Cycle
Auto-Dry Sensor Not Working
Timer Not Advancing
Electric Dryer No Heat — Partial Power
Gas Smell from Gas Dryer
Display Panel Not Working
Buttons Not Responding
Won't Spin at All
Stops Mid-Cycle
Heat Setting Not Changing
Excessive Energy Use
Excessive Static on Clothes
Clothes Heavily Wrinkled
Steam Function Not Working
Moisture Sensor Needs Cleaning
Exhaust Hose Kinked
Exterior Too Hot to Touch
Wrinkle-Prevent Tumble Not Working
Requires Two or More Cycles to Dry
Error Code on Display
Low Gas Pressure to Dryer
Drum Interior Light Not Working
Door Handle Broken
Auto-Dry Cycle Runs All Night
Gas Burner Orifice Clogged
Lint Fire Hazard in Ductwork
Timer Advancing Too Slowly
Three-Prong Outlet / Four-Prong Cord Mismatch
Knocking at Startup
Intermittent Squeaking
Bird or Pest Nest in Dryer Duct
Cycling Thermostat Stuck Closed
Gas Valve Solenoid Kit Needed
Thermal Cutout Needs Resetting