True Fix Houston is your local provider for True Refrigerator repair. Our neighborhood technicians work on True equipment and access to genuine OEM parts. We repair all True Refrigerator models, handle all common problems, and back our work with a 90-day parts and 30-day labor warranty. Book online or call for same-day service near you.
How a Call Actually Goes
Related Services
Houston technicians across every appliance and brand we cover.
True refrigerator repair: what to know
True Manufacturing builds commercial reach-ins, undercounters, glass-door merchandisers and prep tables, and its documentation is written for the business owner who keeps the unit running. True's manual lists R-290, R-513A or R-600a refrigerant for its appliances, and the serial label says which. True tracks each unit's history by serial number and notes that the label location varies by model. The manuals are blunt about the condenser: dirty coils can cause failure, and True recommends checking them every 30 days. On some units the condenser fan reverses to blow dirt off the coil during refrigeration or defrost. True also explains that the control senses evaporator coil or air temperature, not product temperature, and that the most reliable check is the product itself. For a Houston restaurant, bar or convenience store, a True unit near a hot line works hard, and a clogged condenser is the first thing to check when it warms.
Faults we see on True refrigerators
Warm cabinet with a dusty condenser
True warns that dirty coils can cause product failure. In a busy kitchen, grease and lint clog the coil quickly. The tech cleans it with a stiff brush along the fins, a shop vac, or compressed air, CO2 or nitrogen, as True recommends, then checks the condenser fan and compressor.
Thermometer swings up and down
True explains that a dial thermometer or electronic display tracks the refrigeration cycle, so it rises and falls as the compressor cycles, and does not show product temperature. Swings alone are not a fault. The technician probes the product itself, then checks the control's set point and differential before deciding whether the control or sensor has failed.
Compressor slow to start after power-up
True says there may be a short delay before the compressor and fans start, determined by time or temperature, and an initial defrost lasting at least six minutes. Owners often mistake this for a fault. If the delay is much longer, the control and start components are checked.
Water on the floor
True's recommended maintenance includes checking that the drain line is clear, and for good reason. Defrost water that cannot reach the drain pan pools in the cabinet bottom or runs out the front. A clogged line, a pan knocked out of position or a drain heater fault on a freezer are the usual causes, and each is checked.
Gasket worn or torn
True's maintenance schedule includes checking gasket condition and seal. A split or crushed gasket draws in muggy kitchen air, frosts the coil and drives the compressor harder. True says to clean gaskets with warm soapy water and never scrape them with sharp tools. Damaged gaskets are replaced to fit the door.
Check these before you call
- Check the condenser coil every 30 days and clean it as True recommends.
- Never place filter material in front of the condensing coil, as True warns.
- Check product temperature, not just the display.
- Make sure the drain line is clear.
- Inspect gaskets and confirm each door seals.
Finding the model number
True says the serial label location varies by appliance; the label also identifies the refrigerant and electrical ratings. Having it ready lets the technician bring the right part on the first visit.
Repair it or replace it?
True units are built for heavy commercial use, and their parts are widely available. Fans, controls, gaskets, drain parts and defrost components are worth repairing on almost any unit with a sound cabinet. Compressor or sealed-system work requires a technician trained for the refrigerant on the label, including flammable hydrocarbons, and on a cabinet in good shape, it is often still more economical than buying and installing a new one.
True refrigerator questions
How often should the condenser on a True unit be cleaned?
True recommends checking the condenser coil every 30 days and cleaning it as needed, monthly or more in kitchens with fryers or grills. Brush along the fins rather than across them, use a shop vac, or blow CO2, nitrogen or compressed air through. Do not cover the coil with filter material, which True specifically warns against.
Why does the temperature display change so much?
True notes that the control senses evaporator coil or air temperature, not product temperature, and that the display reflects normal cycle swings. A few degrees of movement is expected. The most reliable check is the temperature of the food or drink itself, measured with a probe thermometer at the same spot each day.
Our new True unit did not start cooling right away. Is it faulty?
True says there may be a short delay before the compressor and fans start, set by time or temperature, and that it can include an initial defrost lasting at least six minutes. Give it that time. If the cabinet still is not cooling after the delay has passed, check the plug and breaker, then call for service.