Call Now
OEM Parts appliance repair

OEM Parts

AGA Cooktop Repair Near You — Full Brand List

Local AGA technicians ready to fix your Cooktop near you. Same-day appointments available.

Licensed & insured in TexasSame-day slots90-day parts warrantyAll Houston home types served
(832) 446-4724

Mon–Fri 7am–7pm · Sat 8am–5pm

Request a RepairStep 1 of 2
01 The job
02 Your details
Property
01Property
Where
02Where
What needs fixing
03What needs fixing

Prefer to talk? (832) 446-4724

90-Day
Parts Warranty
Same Day
Availability

Manufacturers We Are Trained On

Samsung appliance repairLG appliance repairWhirlpool appliance repairGE appliance repairBosch appliance repairMaytag appliance repairKitchenAid appliance repairFrigidaire appliance repairElectrolux appliance repairKenmore appliance repairAmana appliance repairMiele appliance repairViking appliance repairThermador appliance repairWolf appliance repairJennAir appliance repairDacor appliance repairSmeg appliance repairFisher & Paykel appliance repair
Houston Repair Technicians

Built for Houston — Homes, Condos & More

True Fix Houston is your local provider for AGA Cooktop repair. Our neighborhood technicians work on AGA equipment and access to genuine OEM parts. We repair all AGA Cooktop models, handle all common problems, and back our work with a 90-day parts and 30-day labor warranty. Book online or call for same-day service near you.

Colonial & Ranch
Houston's most common homes — we service full-size appliances across Greater Houston.
Condo / Townhouse
HOA-approved. Insurance certificates & board documentation on request.
Same-Day Service
Call before noon for today's slot across all Houston zip codes.
All Major Brands
Samsung, LG, Sub-Zero, Miele, Viking & 40+ more.
Upfront Pricing
Flat-rate quotes before work starts — no surprise charges.
90-Day Warranty
90 days on parts, 30 days on labor. We return at no charge if the fix fails.
Licensed & insured in Texas
State-licensed, fully bonded & insured
HOA & Board Ready
Insurance certificates on request
Flexible Scheduling
Mon–Fri 7am–7pm · Sat 8am–5pm
Upfront Fixed Pricing
No hidden fees — price locked before we start

How a Call Actually Goes

01
Start With a Call or the Form
Schedule in 2 min or call (832) 446-4724
02
Tech Arrives
Usually same day in a 3-hr window
03
Diagnose & Quote
Upfront price — no work without approval
04
Fix & Test
Repair done, tested before we leave

AGA cooktop repair: what to know

AGA is the British maker best known for the cast-iron heat-storage cooker with insulated hotplate lids. In American kitchens the AGA name more often appears on its range families, Mercury and Elise among them. On those ranges the cooktop is a built-in section, gas on some versions and induction on others, not a separate unit dropped into the counter, so this page deals with the cooktop section of an AGA range. The Mercury 36 induction model has five zones, and each one has its own pan detector and residual-heat indicator. All five offer a P boost setting, and the two right-hand zones can be bridged for a griddle. Boost power is shared between linked zones, so a zone that seems to weaken when its neighbour goes to P is working as designed. The AGA manual gives the genuine faults their own display codes, and that is where diagnosis starts.

Faults we see on AGA cooktops

Zone weakens when the one beside it is boosted

The owner puts one pan on P and the pan on the zone next to it drops off the boil. On the Mercury 36 induction, AGA pairs the left-front and left-rear zones and also the two right-hand zones for boost, and whichever was switched to P last takes priority. If the unpaired centre zone loses power the same way, something else is wrong, and the technician checks the induction generator and its supply.

E2 after a long session or a pan boiling dry

E2 means the electronics under the glass have run too hot. AGA gives two causes: poor ventilation around the installed range, and a pan left to boil dry. The technician checks for blocked air paths at the base and rear, confirms the internal cooling fan starts, and looks for heat discoloration on the induction board before ordering any parts.

Pan symbol flashing, zone will not heat

The display keeps asking for a pan although one is on the zone. Copper, aluminium and glass-ceramic pans are not detected, and AGA warns that some stainless pans are not induction-compatible either. A small pan on a large ring can also fail detection. If a magnet-friendly flat pan still gets no response, the coil or the pan-detection circuit for that zone is tested.

Er followed by a number

AGA describes Er plus a number as an internal fault the owner cannot clear. AGA's instruction is to consult the installer or a qualified repair engineer. The engineer cuts power at the breaker, reads the code again after restart, then tests the coil, the generator board and the interface board in turn and replaces the part that fails.

Control fascia too hot to touch

AGA ranges have a cooling fan that keeps the control fascia at a safe temperature. A fascia that gets excessively hot is the manual's own sign that this fan may have failed, especially if the oven below is also in use. The tech listens for the fan at start-up, checks its wiring and supply, and replaces the fan before the heat damages the controls.

Check these before you call

  • Hold a fridge magnet to the base of the pan; if it does not grip firmly, that pan will not work on AGA induction.
  • Lay a ruler across the pan base. AGA wants a flat or very slightly upturned base, never a round-bottomed wok.
  • Turn the boosted zone back to 9 and see whether the neighbouring zone recovers its power.
  • Look for a tripped breaker if the display is completely dark; AGA lists loss of supply voltage as the first cause.
  • Wipe the glass and pan base dry before restarting, since residue burns on and can scratch the surface.

AGA cooktop error codes

CodeMeaningTry first
E2The cooktop's electronic unit is too hot; it can also appear if a pan has boiled dry.Switch the zone off, remove the pan and check that the range's ventilation is not blocked. Call for service if E2 keeps returning.
U400The range has been connected to the supply incorrectly; the control switches off after about a second and the code stays on.Stop using the range and have the installer or an electrician check the supply connection.
Er + numberAn internal technical fault that the user cannot fix.Note the full code, turn the breaker off and on once, and book a repair if it reappears.

From AGA's own documentation; codes vary by model, so check your manual.

Repair it or replace it?

An AGA range is an expensive piece of furniture-grade cooking equipment, and its cooktop is part of the same chassis, so replacing it means replacing the range. Pan-detection faults, a failed cooling fan or one dead coil are repairable. The harder case is a cracked glass top combined with a damaged induction generator on an older model, where parts may need to come from overseas. Ask for part availability on the exact model before deciding either way.

AGA cooktop questions

My AGA induction top hums or buzzes with certain pans. Is that a fault?

AGA's manual says some noise from the pan is normal, especially at high settings or with all five zones running. The pan's construction makes a difference too; layered or thin-based pans buzz more. A sharp clicking or rattling from inside the range rather than the pan is different and should be looked at.

Can I use a griddle across two zones?

Only on the two right-hand zones of the Mercury 36 induction, using the bridging function, which you enter by turning both right-hand knobs fully clockwise together. AGA warns against running those two knobs separately under a griddle, because it can overheat and damage the coating, and against using the left or centre zones for a griddle at all.

How long does Power Boost last?

Up to 10 minutes per zone, after which the control drops it to setting 9 automatically. That is a built-in limit, not a failure. If boost cuts out after only a minute or two, or the zone falls well below 9, overheating protection or a weak generator could be the cause.

AGA Cooktop Problems We Fix

Burner Not Working
Uneven Heat Distribution
Won't Ignite
Control Panel Issue
Gas Smell
Cracked Surface
Gas Burner Not Lighting
All Gas Burners Not Lighting
Constant Clicking When Not in Use
Weak or Low Flame
Yellow or Orange Flame
Electric Burner Not Heating
Induction Burner Not Working
Glass Smooth-Top Cracked
Glass Smooth-Top Scratched
Burner Knob Broken or Missing
Control Knob Loose
Gas Valve Failure
Spark Igniter Electrode Failed
Element Switch Failure (Electric)
Burner Won't Turn Off
Hot Surface Indicator Not Working
Gas Smell Without Flame
Error Code on Induction Cooktop
Induction Cooktop Not Detecting Cookware
E7 / E Sensor Error (Induction)
Dark Burn Spot on Smooth-Top
Electric Element Glowing When Turned Off
Induction Cooktop Buzzing Noise
Flex Zone / Expandable Element Not Working
Burner Not Reaching Maximum Power
Grill or Center Burner Not Working
Cooktop Requiring Specific Cookware
Warming Zone on Cooktop Not Heating
Heat Spreading to Adjacent Burner Area
Downdraft Vent Not Working
Surface Element Only Works at Full Power
Radiant Element Cracked or Burned
Igniter Clicking Randomly When Not Cooking
Low Pressure on All Gas Burners
Glass Cooktop Cracked from Thermal Shock
Induction Displaying H After Cooking
Surface Element Heating Intermittently
Gas Burner Lighting Wrong Burner
Cooktop Not Powering On
Not Sure If Cookware Is Induction-Compatible
Ceramic Cooktop Surface Difficult to Clean
Cast Iron Grates Rusting
User Reports Burning Even Though Induction Is Cold
Gas Supply Hose Needs Replacement
Induction Zone Display Flashing
Cooktop Surface Permanently Stained
Electric Cooktop on Wrong Voltage

Other AGA Every Machine in the House

CallBook