True Fix Houston is your local provider for AGA Cooktop repair. Our neighborhood technicians work on AGA equipment and access to genuine OEM parts. We repair all AGA Cooktop models, handle all common problems, and back our work with a 90-day parts and 30-day labor warranty. Book online or call for same-day service near you.
How a Call Actually Goes
Related Services
Houston technicians across every appliance and brand we cover.
AGA cooktop repair: what to know
AGA is the British maker best known for the cast-iron heat-storage cooker with insulated hotplate lids. In American kitchens the AGA name more often appears on its range families, Mercury and Elise among them. On those ranges the cooktop is a built-in section, gas on some versions and induction on others, not a separate unit dropped into the counter, so this page deals with the cooktop section of an AGA range. The Mercury 36 induction model has five zones, and each one has its own pan detector and residual-heat indicator. All five offer a P boost setting, and the two right-hand zones can be bridged for a griddle. Boost power is shared between linked zones, so a zone that seems to weaken when its neighbour goes to P is working as designed. The AGA manual gives the genuine faults their own display codes, and that is where diagnosis starts.
Faults we see on AGA cooktops
Zone weakens when the one beside it is boosted
The owner puts one pan on P and the pan on the zone next to it drops off the boil. On the Mercury 36 induction, AGA pairs the left-front and left-rear zones and also the two right-hand zones for boost, and whichever was switched to P last takes priority. If the unpaired centre zone loses power the same way, something else is wrong, and the technician checks the induction generator and its supply.
E2 after a long session or a pan boiling dry
E2 means the electronics under the glass have run too hot. AGA gives two causes: poor ventilation around the installed range, and a pan left to boil dry. The technician checks for blocked air paths at the base and rear, confirms the internal cooling fan starts, and looks for heat discoloration on the induction board before ordering any parts.
Pan symbol flashing, zone will not heat
The display keeps asking for a pan although one is on the zone. Copper, aluminium and glass-ceramic pans are not detected, and AGA warns that some stainless pans are not induction-compatible either. A small pan on a large ring can also fail detection. If a magnet-friendly flat pan still gets no response, the coil or the pan-detection circuit for that zone is tested.
Er followed by a number
AGA describes Er plus a number as an internal fault the owner cannot clear. AGA's instruction is to consult the installer or a qualified repair engineer. The engineer cuts power at the breaker, reads the code again after restart, then tests the coil, the generator board and the interface board in turn and replaces the part that fails.
Control fascia too hot to touch
AGA ranges have a cooling fan that keeps the control fascia at a safe temperature. A fascia that gets excessively hot is the manual's own sign that this fan may have failed, especially if the oven below is also in use. The tech listens for the fan at start-up, checks its wiring and supply, and replaces the fan before the heat damages the controls.
Check these before you call
- Hold a fridge magnet to the base of the pan; if it does not grip firmly, that pan will not work on AGA induction.
- Lay a ruler across the pan base. AGA wants a flat or very slightly upturned base, never a round-bottomed wok.
- Turn the boosted zone back to 9 and see whether the neighbouring zone recovers its power.
- Look for a tripped breaker if the display is completely dark; AGA lists loss of supply voltage as the first cause.
- Wipe the glass and pan base dry before restarting, since residue burns on and can scratch the surface.
AGA cooktop error codes
| Code | Meaning | Try first |
|---|---|---|
| E2 | The cooktop's electronic unit is too hot; it can also appear if a pan has boiled dry. | Switch the zone off, remove the pan and check that the range's ventilation is not blocked. Call for service if E2 keeps returning. |
| U400 | The range has been connected to the supply incorrectly; the control switches off after about a second and the code stays on. | Stop using the range and have the installer or an electrician check the supply connection. |
| Er + number | An internal technical fault that the user cannot fix. | Note the full code, turn the breaker off and on once, and book a repair if it reappears. |
From AGA's own documentation; codes vary by model, so check your manual.
Repair it or replace it?
An AGA range is an expensive piece of furniture-grade cooking equipment, and its cooktop is part of the same chassis, so replacing it means replacing the range. Pan-detection faults, a failed cooling fan or one dead coil are repairable. The harder case is a cracked glass top combined with a damaged induction generator on an older model, where parts may need to come from overseas. Ask for part availability on the exact model before deciding either way.
AGA cooktop questions
My AGA induction top hums or buzzes with certain pans. Is that a fault?
AGA's manual says some noise from the pan is normal, especially at high settings or with all five zones running. The pan's construction makes a difference too; layered or thin-based pans buzz more. A sharp clicking or rattling from inside the range rather than the pan is different and should be looked at.
Can I use a griddle across two zones?
Only on the two right-hand zones of the Mercury 36 induction, using the bridging function, which you enter by turning both right-hand knobs fully clockwise together. AGA warns against running those two knobs separately under a griddle, because it can overheat and damage the coating, and against using the left or centre zones for a griddle at all.
How long does Power Boost last?
Up to 10 minutes per zone, after which the control drops it to setting 9 automatically. That is a built-in limit, not a failure. If boost cuts out after only a minute or two, or the zone falls well below 9, overheating protection or a weak generator could be the cause.